Values
LIGNATUR elements are CE-labelled and can be calculated according to the European Technical Approval ETA-11 / 0137, the Eurocode and the national standards. Precise analysis of LIGNATUR elements for single-span girders and multi-span girders is limited to checking the moments, lateral forces and deflections. The following tables show the characteristic data of LIGNATUR elements.
Loading ...
Ccharacteristic Values
Fire resistance
Fire resistance REI30
Fire resistance REI60
Fire resistance REI90
Soundproofing
Soundproofing 50kg/m2 fill
Soundproofing silence12
Heat insulation
Heat insulation with mineral fibre
Heat insulation with wood fibre
Room acoustics
Acoustics Type 1
Acoustics Type 2
Acoustics Type 3
Acoustics Type 3.1
Acoustics Type 5
Acoustics Type 5.1
Acoustics Type 6
Acoustics Type 6.1
Acoustics Type 8
Acoustics Type 8.1
Acoustics Type 9
Acoustics Type 9.1
Acoustics Type 1 dynamic design
Acoustics Type 2 dynamic design
Acoustics Type 3 dynamic design
Acoustics Type 3.1 dynamic design
Acoustics Type 5 dynamic design
Acoustics Type 5.1 dynamic design
Acoustics Type 6 dynamic design
Acoustics Type 6.1 dynamic design
Acoustics Type 8 dynamic design
Acoustics Type 8.1 dynamic design
Acoustics Type 9 dynamic design
Acoustics Type 9.1 dynamic design
Element
Surface element t = 31
Surface element t = 40
Box element LKE
Element height
Element height 120 mm
Element height 140 mm
Element height 160 mm
Element height 180 mm
Element height 200 mm
Element height 220 mm
Element height 240 mm
Element height 260 mm
Element height 280 mm
Element height 300 mm
Element height 320 mm
Element height 360 mm
After selection via the drop-down menu, the calculated characteristic values are displayed. The formulae for this can be found in the formulae overview. The resistance values are calculated as a function of the timber strength C24 in accordance with ETA 11/0137.
The visualisation of your selection is simplified. It does not take into account the element height and the acoustic type.
Parameters
Cross section values
Resistance Values
Safety coefficient values
Resistance values in the event of fire
Loading ...
Single-span beam Calculator
Ermitteln Sie mit den oben bestimmten Kennwerten die maximale Spannweite. Wir empfehlen für die maximale Durchbiegung bei Mehrfamilienhaus-, Schulhaus-, und Bürodecken mit Bodenaufbauten = 200 kg/m2 die maximale Anfangsdurchbiegung ≥ l/475 zu wählen, bei Galeriedecken ohne Aufbau und Einfamilienhäuser mit leichten Trockenaufbauten ≥ l/600 bei begehbaren Dächern ≥ l/500 und bei Flachdächern ≥ l/400. [en]
Bending
l/350
l/400
l/450
l/475
l/500
l/550
l/600
Tragfähigkeit | My,d = - kNm | ≤ | RM,y,d = - kNm | |
Vz,d = - kN | ≤ | RV,z,d = - kN | ||
Gebrauchstauglichkeit | winst = - mm | ≤ | l/- | |
Tragfähigkeit im Brandfall | My,d,fi = - kNm | ≤ | RM,y,d,fi = - kNm | |
Vz,d,fi = - kN | ≤ | RV,z,d,fi = - kN | ||
Resultat | Maximal mögliche Spannweite l = - m [en] |
Dlubal Datenbank
Das Dlubal Statikprogramm bietet in Ihrer Datenbank viele LIGNATUR-Kennwerte zur statischen Bemessung unserer LIGNATUR-Decken- und Dachelemente. Besten Dank für die Aufnahme von LIGNATUR in die Dlubal Datenbank.
Ist Ihr gewählter LIGNATUR-Querschnitt nicht mit dabei? Kontaktieren Sie uns, wir nennen Ihnen die exakten Kennwerte.
consulting@lignatur.ch
Statische Verstärkung
Static reinforcement
For structural reinforcement the LIGNATUR elements may be partially fabricated in solid timber.
Static reinforcement
For structural reinforcement the LIGNATUR elements may be partially fabricated in solid timber.